Any required Zoning Permits or Drainage Permits must be obtained prior to the start of work - The submitted construction drawings shall be signed and sealed by an Architect or Engineer licensed in the Commonwealth of Pennsylvania. Construction drawings shall include, but not limited to, the following:
- Foundation Plan indicating:
- Dimensions of the structure and foundation.
- Depth and width of the footings (concrete footings to be a minimum of 36 inches below finished grade, 8 inches thick, and 2,500 psi).
- Size, thickness, and materials used for foundation walls.
- Details on sub-grade material and preparation.
- Floor Plan by level indicating:
- Interior layout and dimensions with bearing and nonbearing partitions.
- Beams and supports with materials, sizes, spacing, and spans.
- Size, spacing, span, and bridging of floor joists.
- Smoke and carbon monoxide detector locations.
- Optional Framing Plan upon Township’s request.
- Roof Plan indicating:
- Size, spacing, and span of ceiling joists.
- Size, spacing, span, and slope of rafters.
- Size of the ridge.
- Size and spacing of collar ties.
- Type, thickness, and R-factor of insulation.
- Details on sheathing, flashing, felt, and shingles.
- Details on roof openings, including attic ventilation, valleys, access, and connections.
- Wall Section indicating:
- Wall plates, stud sizing and placing, type and placement of rack bracing.
- Details of facade materials.
- Clear span for cantilever frame sections and headers above openings.
- Type, thickness, and R-factor of insulation or Res Check for energy compliance.
- Cross Section indicating:
- Foundation and framing members including pre-engineered structural members.
- Certification stamped by an Engineer licensed in the Commonwealth of Pennsylvania for each type of pre-engineered structural members.
- Submit two (2) copies of the electrical wiring diagram approved by one of the Approved Electrical Underwriters attached to this Application.
- Submit two (2) copies of the plumbing system showing the size of all drains, vents, traps and materials.
- For new residential dwellings, submit two (2) copies of the mechanical system showing the duct work, complete heat loss calculation, and specifications.
- For additions or alterations to residential dwellings, submit two (2) copies of the mechanical system showing the duct work and complete heat loss calculation for a new heater. If using an existing heater, the complete heat loss calculation must treat the existing space and addition as one unit.
|